Add pricision_gas_mixer_H2_O2

This commit is contained in:
Ivor Barhansky 2024-07-30 10:52:08 +00:00
parent bc24070e65
commit 063ec72bbb

86
pricision_gas_mixer_H2_O2 Normal file
View File

@ -0,0 +1,86 @@
# H2/O2 Volume Pump Gas Mixer
# Uses 2 Volume pumps instead of a gas mixer
# No need to worry about temperatures throwing...
#...mix ratios off. -Prevents Over pressure.
# You will need 1 Pipe Analyser and 2 Volume pumps.
alias H2o2Analyser d0
alias O2Pump d1
alias H2Pump d2
# ----------Change desired values here-------------
# Currently set for H2/o2 fuel mix.
# If you adujst the max tank pressure then you must
#...modify the the settings below that accordingly.
define O2Ratio 0.34#Set desired O2 ratio
define H2Ratio 0.66 #Set desired H2 ratio
define MaxPres 20000 #Set desired tank pressure
define MaxH2Pres 19800 #Keep below MaxPres
define MinTransPres 19500 #Keep below MaxH2Pres
define MinPres 19000 # Set tank minimum pressure
define PumpHighSetting 10.0 #H2Pump max setting
#--------------------------------------------------
alias O2 r0 #Ratio
alias H2 r1 #Ratio
alias Pres r2 #Pressure
alias H2PumpSetting r3
alias CurrentO2Setting r4
alias CurrentH2Setting r5
alias LowH2Setting r6
checkO2:
s d0 On 1
l H2PumpSetting d2 Setting
mul CurrentO2Setting H2PumpSetting 0.75
s d1 Setting CurrentO2Setting
l O2 d0 RatioOxygen
blt O2 O2Ratio o2PumpON
bgt O2 O2Ratio o2PumpOFF
j checkH2
checkH2:
l Pres d0 Pressure
bge Pres MinTransPres setLOW
blt Pres MinTransPres setHIGH
resumePresCheck:
l Pres d0 Pressure
bge Pres MaxH2Pres h2PumpOFF
H2RatioCheck:
l H2 d0 RatioVolatiles
blt H2 H2Ratio h2PumpON
bgt H2 H2Ratio h2PumpOFF
j checkO2
o2PumpON:
s d1 On 1
j checkH2
o2PumpOFF:
s d1 On 0
j checkH2
h2PumpON:
s d2 On 1
j checkO2
h2PumpOFF:
s d2 On 0
j checkO2
pumpsOFF:
s d1 On 0
s d2 On 0
j checkO2
setLOW:
abs CurrentH2Setting PumpHighSetting
mul LowH2Setting CurrentH2Setting 0.5
s d2 Setting LowH2Setting
j resumePresCheck
setHIGH:
s d2 Setting PumpHighSetting
j resumePresCheck