@ -0,0 +1,86 @@
|
||||
# H2/N2O Volume Pump Gas Mixer
|
||||
|
||||
# Uses 2 Volume Pumps instead of a Gas Mixer
|
||||
# No need to worry about temperatures throwing...
|
||||
#...mix ratios off. -Prevents over pressure.
|
||||
# You will need 1 Pipe Analyser and 2 Volume Pumps.
|
||||
|
||||
alias H2N20Analyser d0
|
||||
alias PumpN20 d1
|
||||
alias PumpH2 d2
|
||||
|
||||
# ----------Change desired values here-------------
|
||||
# Currently set for H2/N2O fuel mix.
|
||||
# If you adujst the max tank pressure then you must
|
||||
#...modify the the settings below that accordingly.
|
||||
|
||||
define N2ORatio 0.50 #Set desired N2O ratio
|
||||
define H2Ratio 0.50 #Set desired H2 ratio
|
||||
define MaxPres 700 #Set desired tank pressure
|
||||
define MaxH2Pres 680 #Keep below MaxPres
|
||||
define MinTransPres 650 #Keep below MaxH2Pres
|
||||
define MinPres 600 # Set tank minimum pressure
|
||||
define PumpHighSetting 10.0 #H2Pump max setting
|
||||
#--------------------------------------------------
|
||||
|
||||
alias N2O r0 #Ratio
|
||||
alias H2 r1 #Ratio
|
||||
alias Pres r2 #Pressure
|
||||
alias H2PumpSetting r3
|
||||
alias CurrentN2OSetting r4
|
||||
alias CurrentH2Setting r5
|
||||
alias LowH2Setting r6
|
||||
|
||||
checkN2O:
|
||||
s H2N20Analyser On 1
|
||||
l H2PumpSetting PumpH2 Setting
|
||||
mul CurrentN2OSetting H2PumpSetting 0.75
|
||||
s PumpN20 Setting CurrentN2OSetting
|
||||
l N2O H2N20Analyser RatioNitrousOxide
|
||||
blt N2O N2ORatio n2OPumpON
|
||||
bgt N2O N2ORatio n2OPumpOFF
|
||||
j checkH2
|
||||
|
||||
checkH2:
|
||||
l Pres H2N20Analyser Pressure
|
||||
bge Pres MinTransPres setLOW
|
||||
blt Pres MinTransPres setHIGH
|
||||
resumePresCheck:
|
||||
l Pres H2N20Analyser Pressure
|
||||
bge Pres MaxH2Pres h2PumpOFF
|
||||
h2RatioCheck:
|
||||
l H2 H2N20Analyser RatioVolatiles
|
||||
blt H2 H2Ratio h2PumpON
|
||||
bgt H2 H2Ratio h2PumpOFF
|
||||
j checkN2O
|
||||
|
||||
n2OPumpON:
|
||||
s PumpN20 On 1
|
||||
j checkH2
|
||||
|
||||
n2OPumpOFF:
|
||||
s PumpN20 On 0
|
||||
j checkH2
|
||||
|
||||
h2PumpON:
|
||||
s PumpH2 On 1
|
||||
j checkN2O
|
||||
|
||||
h2PumpOFF:
|
||||
s PumpH2 On 0
|
||||
j checkN2O
|
||||
|
||||
pumpsOFF:
|
||||
s PumpN20 On 0
|
||||
s PumpH2 On 0
|
||||
j checkN2O
|
||||
|
||||
setLOW:
|
||||
abs CurrentH2Setting PumpHighSetting
|
||||
mul LowH2Setting CurrentH2Setting 0.5
|
||||
s PumpH2 Setting LowH2Setting
|
||||
j resumePresCheck
|
||||
|
||||
setHIGH:
|
||||
s PumpH2 Setting PumpHighSetting
|
||||
j resumePresCheck
|