stationeers_ic10/heating_cooling.ic10

77 lines
1.9 KiB
Plaintext
Raw Normal View History

alias gas_sensor d0
alias thermostat d1 # Logic Switch, Dial variant (Max=30)
alias temp_variance d2 # Logic Memory, must be more than 0 (2 is a good value)
alias curr_temp r0
alias target_temp r1
alias variance r2
alias min_temp r3
alias max_temp r4
alias cooling_active r5
alias heating_active r6
define wall_heaters 24258244 # Wall Heaters
define wall_coolers -739292323 # Wall Coolers (Gas)
define liquid_wall_coolers -1369060582 # Wall Coolers (Liquid)
define temp_convert 273
start:
# establish min- and max-temps to registry
l variance temp_variance Setting
l min_temp thermostat Setting
sub min_temp min_temp variance
l max_temp thermostat Setting
add max_temp max_temp variance
# initiate target temperature
l target_temp thermostat Setting
# read ambient temp from sensor and convert to C
l curr_temp gas_sensor Temperature
sub curr_temp curr_temp temp_convert
# compare current temp to max/min temp and
# initiate cooling or heating if needed
bgt curr_temp max_temp cooling
blt curr_temp min_temp heating
yield
# Go to start again
j start
cooling:
# read ambient temp from sensor and convert to C
l curr_temp gas_sensor Temperature
sub curr_temp curr_temp temp_convert
# test if coolers need to be on or not
sgt cooling_active curr_temp target_temp
# send state to coolers
sb wall_coolers On cooling_active
sb liquid_wall_coolers On cooling_active
yield
# if curr_temp is lower than target, keep cooling
bgt curr_temp target_temp cooling
# ...if not, go to start again
j start
heating:
# read ambient temp from sensor and convert to C
l curr_temp gas_sensor Temperature
sub curr_temp curr_temp temp_convert
# test if heaters need to be on or not
slt heating_active curr_temp target_temp
# send state to heaters
sb wall_heaters On heating_active
yield
# if curr_temp is lower than target, keep heating
blt curr_temp target_temp heating
# ...if not, go to start again
j start