stationeers_ic10/heating_cooling.ic10
2021-11-10 17:29:01 +01:00

83 lines
1.7 KiB
Plaintext

alias gas_sensor d0
# d1= Logic Switch, Dial variant (Max=30)
alias thermostat d1
# d2 = Logic Memory, must be more than 0
alias temp_variance d2
# d3 = Console, LED Display variant, optional
alias temp_disp d3
alias curr_temp r0
alias target_temp r1
alias variance r2
alias min_temp r3
alias max_temp r4
alias cooling_active r5
alias heating_active r6
define wall_heaters 24258244
define wall_coolers -739292323
define liquid_wall_coolers -1369060582
define temp_convert 273.15
start:
yield
# establish min- and max-temps to registry
l variance temp_variance Setting
l min_temp thermostat Setting
sub min_temp min_temp variance
l max_temp thermostat Setting
add max_temp max_temp variance
# initiate target temperature
l target_temp thermostat Setting
# read ambient temp from sensor and convert to C
l curr_temp gas_sensor Temperature
sub curr_temp curr_temp temp_convert
# update display
brdns temp_disp 2
jal display
# compare current temp to max/min temp and
# initiate cooling or heating if needed
bgt curr_temp max_temp cooling
blt curr_temp min_temp heating
j start
display:
s temp_disp Setting curr_temp
j ra
cooling:
# test if coolers need to be on or not
sgt cooling_active curr_temp target_temp
# update display
brdns temp_disp 2
jal display
# send state to coolers
sb wall_coolers On cooling_active
sb liquid_wall_coolers On cooling_active
bgtz cooling_active cooling
j start
heating:
# test if heaters need to be on or not
slt heating_active curr_temp target_temp
# update display
brdns temp_disp 2
jal display
# send state to heaters
sb wall_heaters On heating_active
bgtz heating_active heating
j start