stationeers_ic10/automated_canister_filling.ic10
2021-09-04 13:02:35 +02:00

58 lines
1.5 KiB
Plaintext

# automatic gas-canister filler.
# only works with player-made cans, starter-cans
# have different hashes that won't work
# !!! Remember to set volume pump to no more !!!
# !!! than 10l! I have mine at 2l for safety !!!
alias canister_storage d0
alias fill_pump d1
alias evac_pump d2
alias analyzer d4
alias canister_present r0
alias canister_hash r1
alias storage_pressure r2
alias gas_to_move r3
alias fill_pressure r4
alias pump_active r5
define canister 42280099
define smart_canister -668314371
start:
yield
# check if canister is present
ls canister_present canister_storage 0 Occupied
# identify canister
ls canister_hash canister_storage 0 OccupantHash
# set safe fill-pressure
beq canister_hash canister regular
beq canister_hash smart_canister smart
regular:
move fill_pressure 8000000 # regular can safe max
j fill # start filling
smart:
move fill_pressure 18000000 # smart can safe max
j fill # start filling
fill: # fills canister if present and <8Mpa
# get canister pressure in Pa
ls storage_pressure canister_storage 0 Pressure
# is there room in the canister for more gas?
slt gas_to_move storage_pressure fill_pressure
# is there a can in the slot that has room?
and pump_active gas_to_move canister_present
# trigger fill pump
s fill_pump On pump_active
beqz canister_present evac# break if no can
j start
evac: # evacuates pipe on can removed and >0Pa
l storage_pressure analyzer Pressure
# is there gas in the pipe?
sgt gas_to_move storage_pressure 0
# trigger evac pump
s evac_pump On gas_to_move
j start